A fire detection system detects smoke or heat and raises the alarm with sounders and beacons. In a conventional system the detectors are connected in zones and the panel shows the zone of the alarm. In an addressable system each device has its own address, so the panel shows which detector or call point was activated.

Comelit offers both systems, with panels, detectors, manual call points, sounders and bases.

Conventional or addressable system

Comelit conventional fire detection panel

Conventional fire detection system

Detectors and call points are connected to zones of the panel. Comelit conventional fire detection panels have 4 zones, 8 zones or 8 to 16 zones.

See the conventional system

Comelit LOGIFIRE EASY addressable fire detection panel

LOGIFIRE addressable system

Each detector, call point and sounder is connected to the panel loop with its own address. The LOGIFIRE EASY 41CPE112 and LOGIFIRE 41CPE118 panels support up to 2 and up to 8 loops respectively. On the 41CPE112, the 41ECL022 loop card controls up to 250 devices.

See the addressable system

Comelit multi-sensor smoke and heat detector

Detectors, call points and sounders

There are optical smoke detectors, heat detectors and multi-sensor smoke and heat detectors, as well as manual call points, sounders, bases with a sounder or beacon and remote LED indicators.

See all fire detection products

EN 54 standards

Fire detection devices are certified to the parts of the European standard EN 54. On Comelit products you will see, depending on the device:

  • EN 54-7 for smoke detectors.
  • EN 54-5 for heat detectors.
  • EN 54-11 for manual call points.
  • EN 54-3 for sounders and sounder bases.
  • EN 54-17 for the short-circuit isolators built into addressable detectors, bases and call points.
  • EN 54-13 for the compatibility of the system components.

What the cost depends on

  • How many rooms and floors will be covered.
  • How many detectors, call points and sounders are needed.
  • Whether a conventional or an addressable system will be installed.
  • Whether the system will be connected to other building systems.

Send us these details using the form and we will get back to you.

Frequently asked questions

In a conventional system detectors and call points are connected in zones and the panel shows in which zone the alarm was raised. In an addressable system each device has its own address on the loop, so the panel shows exactly which detector or call point was activated.

The fire detection panel, smoke or heat detectors with their bases, manual call points and sounders or beacons. In an addressable system, input and output modules and expansion cards can be added.

On the rooms and floors to be covered, on how many detectors, call points and sounders are needed, on whether a conventional or an addressable system will be installed and on the connection to other building systems.

Installation is carried out by a technical installer. You can find Comelit partners by area on the partner map.

Ask us about a fire detection system

Tell us what space you want to protect and how many floors it has. We will contact you as soon as possible.