Gateway that integrates the MIDEA® air conditioning system with the BUSing® control system. It connects to a MIDEA® domestic air conditioning unit through a direct connection with a 2-conductor (2-wire) cable.
Technical data ING-BUSING-MD-D
- Controls one MIDEA® domestic indoor air conditioning unit
- Wiring: direct 2-wire connection without polarity
- Functions: on/off, operating mode, fan speed and setpoint temperature
- Supply voltage 12 Vdc from the BUS, consumption 25 mA
- Dimensions 50 x 55 x 14 mm
- Concealed installation near the A/C unit or inside the ceiling
Function and use ING-BUSING-MD-D
The ING-BUSING-MD-D gateway is an interface that connects to the BUS terminals marked HA and HB on the MIDEA® indoor unit. The operating mode can be cooling, heating, fan, drying or automatic. Fan speed can be set to low, medium or high. The setpoint temperature is set individually and the gateway reads the measured temperature.
Master/slave operation is not supported. The MIDEA® gateway works with or without a unit remote controller connected, and the last command received takes priority.
Installation ING-BUSING-MD-D
The gateway configuration is created in SIDE and uploaded through the BUSing® cable. The maximum BUS distance between devices is 300 m. The operating temperature of the air conditioning gateway is from -10 °C to 55 °C.
Product code: ING-BUSING-MD-D. See also in the Climate/Air Quality category: ORIGEN-PANASONIC GATEWAY, ECOI AND PACI and ORIGEN ACTUATOR FOR LOUVRES (A/C ZONING).